BNDYQ - SF99 SOLVENT KAMPEL BLEND 3293

  • MSDS: BNDYQ
  • Manufacturer: KAMPEL ENTERPRISES INC
  • Product Name: SF99 SOLVENT KAMPEL BLEND 3293
  • National Stock Number: 6850-00F022253
Product Identification

Product ID:SF99 SOLVENT KAMPEL BLEND 3293
MSDS Date:04/20/1990
FSC:6850
NIIN:00F022253
MSDS Number: BNDYQ

Responsible Party
KAMPEL ENTERPRISES INC
8930 CARLISLE ROAD
WELLSVILLE, PA 17365
US

Emergency Phone: (800) 424-9300

Info Phone: (800) 424-9300

Cage: 2L263

Contractor
KAMPEL ENTERPRISES INC
157 WELLSVILLE, PA 17365-0157 US

Telephone: 800-457-4280

Cage: 2L263

Ingredients

TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: >9%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


2-BUTANONE (METHYL ETHYL KETONE) (MEK)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: >9%

OSHA PEL 200 PPM

ACGIH TLV: 590 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOPROPANOL (ISOPROPYL ALCOHOL), 2-PROPANOL, DIMETHYL

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: >9%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM


METHYL ISOAMYL KETONE, MIAK, 5-METHYL-2-HEXANONE

CAS: 110-12-3

RTECS: MP3850000

Fraction By Weight: >9%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM; 9293

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: ANESTHETIC. INHALATION:
RESPIRATORY TRACT IRRITATION & NERVOUS SYSTEM DEPRESSION.
EYES/SKIN: IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INGESTION: ANESTHETIC. INHALATION: RESPIRATORY
TRACT IRRITATION & NERVOUS SYSTEM DEPRESSION. EYES/SKIN:
IRRITATION.

First Aid

First Aid:SKIN/EYES: FLUSH W/PLENTY OF WATER FOR 15 MIN. INHALATION:
REMOVE TO FRESH AIR, IF BREATHING IS DIFFICULT GIVE OXYGEN. IF
BREATHING STOPS GIVE ARTIFICIAL RESPIRATION. INGESTION: CALL
PHYSICIAN IMMEDIA TELY. DON'T INDUCE VOMITING. HAVE PATIENT LIE
DOWN & KEEP WARM. VOMITING MAY LEAD TO ASPIRATION INTO LUNGS WHICH
MAY BE FATAL. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point Method:TCC
Flash Point:28F
Upper Limits:1.7%
Extinguishing Media:NFPA CLASS B EXTINGUISHER (CO2 OR FOAM) FOR CLASS 1
B LIQUID FIRES.
Fire Fighting Procedures:WATER SPRAY CAN PROTECT FIRE FIGHTERS & COOL
CLOSED CONTAINERS. USE FOG NOZZLES IF WATER IS USED.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE IF EXPOSED
TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:SMALL-MOP W/ABSORBENT MATERIAL & TRANSFER TO
HOOD. LARGE-STOP SPILL, DIKE AREA TO PREVENT SPREAD. PUMP LIQUID TO
SALAVAGE TANK & ABSORB REMAINDER & SHOVEL INTO CONTAINERS.

Handling

Handling and Storage Precautions:DON'T STORE >120F. STORE LARGE AMOUNTS
IN STRUCTURES MADE FOR OSHA CLASS 1 B LIQUIDS.
Other Precautions:AVOID FREE FALL OF LIQUID. GROUND CONTAINERS WHEN
POURING. DON'T FLAME CUT SAW, BRAZE, OR WELD. EMPTY CONTAINER
HAZARDOUS.

Exposure Controls

Respiratory Protection:NIOSH/OSHA APPROVED AIR PACK
Ventilation:LOCAL EXHAUST
Protective Gloves:IMPERVIOUS
Eye Protection:GOGGLES
Supplemental Safety and Health
BOILING RANGE: 172-297F

Chemical Properties

Boiling Pt:B.P. Text:SEE SUPP
Vapor Pres:31.0
Vapor Density:3.0
Spec Gravity:0.836
Evaporation Rate & Reference:(ETHER=1) 5.8
Appearance and Odor:CLEAR WATER-WHITE, KETONE ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS SUCH AS PERMANGANATE
Stability Condition to Avoid:HEAT, SPARKS, NON-EXPLOSION PROOF ELECTRIC
EQUIPMENT & OPEN FLAME.
Hazardous Decomposition Products:C0 & CO2

Disposal

Waste Disposal Methods:SMALL-EVAPORATE UNTIL ALL VAPORS ARE GONE.
LARGE-RECYCLE OR INCINERATE. DISPOSE OF IN ACCORDANCE W/LOCAL,
FEDERAL & STATE REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.